Agilent 54610B/54615B/54616B Specifications/Characteristics
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   



Agilent 54610B/54615B/54616B Specifications/Characteristics


Vertical System
Channels 2
Bandwidth (-3dB) 1 dc to 500 MHz
AC Coupled 1 10 Hz to 500 MHz
Max sample rate: 54610B       20 MS/s
54615B       1 GS/s
54616B       2 GS/s
Sensitivity 2mV/div to 5 V/div
Accuracy2 ±2%
Vernier Accuracy2 ±2%
Rise Time 700 ps (calculated)
Coupling dc, ac, and ground
Input R 1 MΩor 50 Ω
Input C ~9 pF
Bandwidth Limit approximately 30 MHz
Inversion CH 1 and CH 2
CMRR ³20 dB at 50 MHz
Dynamic Range ± 12 div from center  screen
Maximum Input 250 V (dc + peak ac) for  5 Vms in 50 Ωmode
50 ΩProtection Protects 50 Ωload from excessive voltage
Probe Sense Automatic readout of 1X, 10X, 20X, and 100X probes
Voltage Measurement Accuracy
Single Cursor3 Vertical Accuracy ± 1.2% of full scale ± 0.5% of position value
Dual Cursor3 Vertical Accuracy ± 0.4% of full scale
Math Functions CH1 + or - CH2
Horizontal System
Main and Delayed
Main Sweep Range 5 s/div to 1 ns/div
Delayed Sweep Range Up to 200X main sweep, as fast as 1 ns/div
Accuracy 54610B    ± 0.01%  
54615B/16B     ±0.005%
Resolution 54610B    5 ps  
54615B/16B    20 ps
Delay Jitter 54610B    10 ppm  
54615B/16B £1 ppm
Pretrigger Delay (negative time)
54610B ³10 divison
54615B The greater of 30 μ s or 60 div, not to exceed 100s
54616B The greater of 15 μs or 60 div, not to exceed 100s
Posttrigger Delay
(Trigger to start of sweep)
The greater of 10 ms 20,000 div, not to exceed 100 s
Time Skew Adjustable over a range of ± 25 ns to remove effects of cabling and probe delays  
Roll Mode At sweep speeds of 200 ms/div or slower, waveform data moves across the display from right to left with no dead time. Display can be free running (nontriggered) or triggered to stop on a trigger event.
Time Measurement Accuracy
Cursor accuracy ± 0.005% of reading.
∆t & 1/∆t ± 0.2% of full scale,
± 100 ps
Trigger System
Internal Triggering
Sensitivity (Ch 1 and 2)
dc to 100 MHz: 0.5 div or 5 mV
100 MHz to 500 MHz: 1 div or 10 mV
Coupling ac, dc, HF reject, LF reject, and noise reject (LF & HF reject -3dB at approx. 50 kHz)
Modes Auto, Autolevel, Normal, Single, & TV
External Triggering
Range ± 2V
Sensitivity:
dc to 100 MHz: < 75mV
100 MHz to 500 MHz: < 150mV
Coupling dc, ac
Input R&C 1 MΩ, ~12 pF or 50 Ω selectable
Maximum Input 250 V (dc + peak ac) or 5Vrms in 50 Ωmode
50 ΩProtection Protects 50 Ωload from excessive voltage
Probe Sense Automatic readout of 1X, 10X, 20X, and 100X probes
TV Triggering TV line and field. 0.5 div of composite sync for stable display (Ch 1 and Ch 2)
Line Counting Delay time calibrated in NTSC and PAL line numbers
All Field Trigger Oscilloscope triggers on the vertical sync pulse in both fields, allowing use with noninterlaced video
Holdoff Adjustable from 300 ns to approximately 13 ns
X-Y Operation
Bandwidth X and Y same as vertical system
Phase Difference ± 3°at 100 kHz (54610B)
± 3°at 10 MHz
(54615B/16B)  
Display System
Display 7-in raster CRT
Resolution 255 vertical by 500 horizontal points
Controls Front-panel intensity control
Graticule 8x10 grid or frame
Autostore Saves previous sweeps in half bright display and the most recent sweep in full bright
Acquisition System
Max Sample Rate 20 MSa/s (54610B)
(single shot) 1 GSa/s (54615B)
2 GSa/s (54616B)
Resolution 8 bits
Simultaneous Channels 2
Record Length £4,000 (54610B)
£5,000 (54615B/16B)
Usable Single-Shot 2 MHz (54610B)
Bandwidth 250 MHz (54615B)
500 MHz (54616B)
Peak Detect 50 ns glitch capture (54610B)
1 ns glitch capture (54615B/16B)
Average Number of averages selectable at 8, 64, 256
Advanced Functions
Automatic Measurements Measurements are continuously updated
Voltage Vavg, Vrms, Vp-p, Vtop, Vbase, Vmin, and Vmax
Time Frequency, Period, +Width, -Width, Duty Cycle, Rise Time, and Fall Time
Cursors Manually or automatically placed
Setup Functions
Autoscale Sets the vertical and horizontal deflection and the trigger level. Requires a  signal with > 0.5% duty cycle, > 49Hz frequency, and > 20 mVp-p
Trace Memory Two volatile pixel memories
General
Power Line Requirements
Line Voltage Range 100 Vac to 240 Vac
Line Voltage Selection Automatic
Line Frequency 45 Hz to 440 Hz
Max Power 220 VA (54610B)
Consumption 300 VA (54615B/16B)
Environmental Characteristics
The instruction meets the requirements to MIL-T-28800E for Type III, Class 3, Style D equipment as described below.
Ambient Temperature
Operation -10°C to +55°C
Nonoperation -51°C to +71°C
Humidity [1]
Operating 95% RH at 40°C for 24 Hrs
Nonoperating 90% RH at 65°C for 24 Hrs
Altitude
Operating to 4,500 m (15,000 ft.)
Nonoperating to 15,000 m (50,000 ft.)
EMI (commercial) CISPR11 Group 1 Class A
EMI (MIL-T-28800E) EMI meets the requirements in accordance with MIL-T-28800E (prior to Interim Amendment 1) and MIL-STD 461C as described below.
CE01 Part 2 narrow band requirements up to 15 kHz
CE03 Part 2
CS01 Part 2
CS02 Part 2 limited to 100 MHz
CS06 Part 5 limited to 400 V
RE01 Part 5 measured at 6 inches, exceptioned from 19 kHz to 50 kHz.
RE02 Part 2 (limited to 1 GHz)full limits of Class A1c and A1f, with Option 002 installed. Without Option 002 installed 10 dB relaxation, 14 kHz to 100 kHz.
RS03 Part 2, limited to 1V/meter from 14 kHz to 1 GHz. Slight trace susceptibility from 450 MHz to 600 MHz and at 950 MHz.
Vibration
Operating 15 minutes along each of the 3 major axes; 0.025 inch p-p displacement, 10 Hz to 55 Hz in one minute cycles. Held for 10 minutes at 55 Hz (4 g at 55Hz).
Nonoperating Survival random vibration, 5 Hz to 500 Hz at 2.41 g rms
Shock Operating: 30 g, 1/2 sine, 11 ms duration, 3 shocks per axis along major axis, total of 18 shocks.
Size (excluding handle)
Height 172 mm (6.8 in)
Width 322 mm (12.7 in)
Depth 317 mm (12.5 in)
Weight 6.6 kg (145 lbs)
Safety CSA Certification, IEC ----- 1010

  1. Upper bandwidth reduced 2 MHz per degree Celsius above 35°C.
  2. Temperature ± 10°C from calibration.
  3. Magnification is used below 7 mV/div range. Below 7 mV/div dull scale is defined as 56 mV full scale.



   