Agilent 3458A Digital Multimeter

Click image to enlarge
Agilent 3458A
|
|
Features:
- 8 ½ digits with 10 nV DC resolution
- 8-ppm 1 year dcV accuracy, optional 4-ppm
- 0.05 ppm dcV transfer accuracy
- 100,000 readings per second at 4 ½ digits
- 2- and 4-wire ohms measurements with offset compensation
- Superior AC voltage measurements
- For complete details, click on the data sheet link
|
Description
The Agilent 3458A Multimeter, recognized the world over as the standard in high performance DMMs,
provides both speed and accuracy in the R&D lab, on the production test floor, and in the calibration lab.
The Agilent 3458A is simply the fastest, most flexible, and most accurate multimeter ever offered by Agilent
Technologies. In your system or on the bench, the Agilent 3458A saves you time and money with unprecedented
test system throughput and accuracy.
Select a reading rate of 100,000 readings per second for maximal test throughput. Or achieve highest levels
of precision with up to 8.5 digits of measurement resolution and 0.1 part per million transfer accuracy. Add this
to the Agilent 3458A´s simplicity of operation, and you have the ideal multimeter for your most demanding applications.
The Agilent Technologies 3458A Multimeter shatters long-standing performance barriers of speed and accuracy on the production
test floor, in R&D, and in the calibration lab. The 3458A is simply the fastest, most flexible, and
most accurate multimeter ever offered by Agilent Technologies. In your system or on the bench,
the 3458A saves you time and money with unprecedented test system throughput and accuracy,
seven function measurement flexibility, and low cost of ownership.
Select a reading rate of 100,000 readings per second for maximal test throughput. Or achieve highest levels of precision with
up to 8.5 digits of measurement resolution and 0.1 part per million transfer accuracy. Add to this,
programming compatibility through the Agilent Multimeter Language (ML) and the 3458A’s
simplicity of operation and you have the ideal multimeter for your most demanding applications.
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| 34401A |
Digital multimeter, 6.5 digit |
| $1070.00 |  |
|
| 3458A |
3458A Digital multimeter, 8.5 digit |
| $8484.00 |  |
|
| 34970A |
Data Acquisition/Switch Unit |
| $1558.00 |  |
|
| 34420A |
34420A Nanovolt/micro-ohm meter, 7.5 digit |
| $4011.00 |  |
|
| Model |
Options |
List Price |
Sale Price |
| 3458A-001 |
Extended Memory |
| $693.00 |  |
|
| 3458A-002 |
High stability 4 ppm per year reference |
| $1351.35 |  |
|
| 3458A-907 |
Front handle kit |
| $69.77 |  |
|
| 3458A-908 |
Rack flange kit |
| $48.04 |  |
|
| 3458A-909 |
Rack flange and front handle kit |
| $106.05 |  |
|
| 3458A-A6J |
ANSI Z540 compliant calibration |
| $354.90 |  |
|
| 11059A |
Kelvin probe set |
| $156.00 |  |
|
| 11060A |
S.M.D. test probe |
| $30.56 |  |
|
| 11062A |
Kelvin clip |
| $28.89 |  |
|
| 34131 |
Please call or email us for pricing and availability. |
| 34132B |
Deluxe test lead set for 3458A |
| $49.22 |  |
|
| 34161A |
Accessory pouch for 34401A, 33120/250A, 34970A, 53131A, etc. |
| $43.32 |  |
|
| 34171A |
Input terminal block for the 34401A DMM (qty. two per) |
| $103.00 |  |
|
| 34172A |
Input calibration short for the 34401A DMM (qty. two per) |
| $103.00 |  |
|
| 34330A |
Current Shunt, 30 Amp, for HP Dmm's |
| $80.76 |  |
|
| 34812A |
Please call or email us for pricing and availability. |
| 34132B |
Deluxe test lead set for 3458A |
| $49.22 |  |
|
| E2308A |
Thermistor temperature probe 0-70 degrees C, 5k ohm |
| $61.12 |  |
|
Specifications
|
Function-Range-Measurement
|
|
The time required to program via GPIB a new measurement configuration, trigger a reading, and return the result to a controller with the following instrument
setup: PRESET FAST; DELAY 0; AZERO ON; OFORMAT SINT; INBUF ON; NPLC 0. |
| TO-FROM configuration description |
GPIB rate1 |
Subprogram rate |
| DCV £ 10 V to DCV £ 10 V |
180 / sec |
340 / sec |
| any DCV / OHMS to any DCV / OHMS |
85 / sec |
110 / sec |
| any DCV / OHMS to any DCV / OHMS with DEFEAT ON |
150 / sec |
270 / sec |
| TO or FROM any DCI |
70 / sec |
90 / sec |
| TO or FROM any ACV or ACI |
75 / sec |
90 / sec |
|
Selected operating rates2
|
| |
Rate
|
| DCV Autorange Rate (100 mV to 10 V) |
110 / sec |
| Execute simple command changes (CALL, OCOMP, etc.) |
330 / sec |
| Readings to GPIB, ASCII |
630 / sec |
| Readings to GPIB, DREAL |
1000 / sec |
| Readings to GPIB, DINT |
50,000 / sec |
| Readings to internal memory, DINT |
50,000 / sec |
| Readings from internal memory to GPIB, DINT |
50,000 / sec |
| Readings to GPIB, SINT |
100,000 / sec |
| Readings to internal memory, SINT |
100,000 / sec |
| Readings from internal memory to GPIB, SINT |
100,000 / sec |
| Maximum internal trigger reading rate |
100,000 / sec |
| Maximum external trigger reading rate |
100,000 / sec |
|
Memory |
| |
Standard |
Options 001 |
| |
Readings |
Bytes 001 |
Readings |
Bytes 001 |
| Reading Storage ( 16 bit ) |
10,240 |
20 k |
+65,536 |
+128 k |
| Non-volatile, for subprograms and/or state storage |
|
14 k |
|
|
|
Delay time |
Timer |
| Accuracy |
± 0.01% ± 5 ns |
Accuracy |
± 0.01% ± 5 ns |
| Maximum |
6000 s |
Maximum |
6000 s |
| Resolution |
10 ns |
Resolution |
100 ns |
| Jitter |
50 ns pk-pk |
Jitter |
<100 ps rms |
- Using HP 9000 Series 350.
- SINT data is valid for APER £10.8 ms.
|