| Input Voltage |
115/230VAC ± 15% 47 - 63Hz Auto-ranging available |
| Input Protection |
Thermal fuse (internal) Inrush current limiting Input breaker |
| Input Isolation |
2250VDC input to chassis 4300VDC input to output, 8mm spacing 500VDC output to chassis |
| Full compliance to IEC950, CSA 22-2-950 and UL 1950 |
| Output Voltages |
Standard output voltage range is 0-60VDC/18A max Consult factory for other voltage ranges |
| Output power |
Limited to 500W on LPS500 and 1000W on LPS 1000. |
| Line/Load Regulation |
±1% combined |
| Output Overvoltage Protection |
30 or 62V selectable, trips AC breaker |
| Overload Protection |
Current limiting with short circuit protection Self-resetting thermostat for thermal protection |
| Efficiency |
Min 80% at full load |
| RFI Suppression |
EN 55022 Class B conducted emissions |
| Output Ripple/Noise |
Better than 1% of output voltage peak to peak or 0.2% RMS of the output voltage (20HZ BW) |
| Operating Temperature |
0 to +50 °C |
| Temperature Drift |
0.03% per °C over operating temperature range |
| Dimensions |
LPS 500: 7” x 15” deep x 10” LPS 1000: 7” x 15” deep x 19” |
| Connections |
Input: IEC320 socket Output: banana sockets |
| Warranty |
Twelve months subject to application within good engineering practice. |