| Input Voltage |
95V - 264V universal 47-63Hz |
| Input Protection |
Thermal fuse (internal) Inrush current limiting |
| Input Isolation |
2250VDC input to chassis 4300VDC input to output, 8mm spacing 500VDC output to chassis |
| Full compliance to IEC950, CSA 22-2-950 and UL 1950 |
| Output Voltages |
LPS 150-30 : 0 - 30VDC/5A LPS 150-60 : 0 - 60VDC/2.5A Consult factory for other voltage ranges |
| Line/Load Regulation |
±1% combined |
| Overload Protection |
Current limiting with short circuit protection. Self-resetting thermostat for thermal protection |
| Efficiency |
Min 80% at full load |
| RFI Suppression |
Meets requirements of EN55022 Class B |
| Output Ripple/Noise |
Better than 1% of output voltage peak to peak or 0.2% RMS of the output voltage (20HZ BW) |
| Operating Temperature |
0 to +50 °C |
| Temperature Drift |
0.03% per °C over operating temperature range |
| Dimensions |
5” x 6.5” x 12” deep |
| Connections |
Input: Standard IEC 320 connector. Output: banana sockets |
| Warranty |
Twelve months subject to application within good engineering practice. |