  • Measurement range of 100AAC/150ADC & 1000AAC/1500ADC
  • Conforms to EN 61010, 600V Cat. III
  • Designed for DMMs, recorders, oscilloscopes, power and harmonic meters, recorders, oscilloscopes, power and harmonic meters



  Description

The MR521 is a general purpose 1500AAC or DC current probe designed for use with DMMs, loggers, oscilloscopes and other instruments that have voltage inputs. The MR521 has dual selectable range probes. The MR521 has an integral 5 ft (1.5m) lead terminated by shrouded banana plugs. The jaw design on these probes make then well-suited for measuring current in both cable and bus bar type conductors.



  Models, Options, & Accessories


Model Description List Price Sale Price
1200.69 AC/DC Current Probe Model MR521 (150A-10mV/A, 1500A-1mV/A, Lead)
$314.00
You may qualify for better pricing.
Please call 877-742-TEST (8378)
or Email for details.
Model Accessories List Price Sale Price
1017.45 Adapter 4mm Non-insulated for Safety Leads
$15.50
You may qualify for better pricing.
Please call 877-742-TEST (8378)
or Email for details.
2111.32 Adapter Banana (Male) BNC (Female)
$27.00
You may qualify for better pricing.
Please call 877-742-TEST (8378)
or Email for details.



  Specifications

Electrical Specifications
Operating Range 0.2 to 1500A
Operating Range
RangeVal 150A, 1500A
Current Range 0.2 to 100AAC (150A Peak); 0.4 to 150ADC, 0.5 to 1000AAC (1500A Peak); 0.5 to 1500ADC
Frequency Range DC to 10kHz at -3dB
Common Mode Voltage 600VAC
Current Overload 3000ADC and 2000AAC continuous up to 1kHz
Insertion Impedance 0.39mW @ 50Hz, 58mW @ 1000Hz
Load Impedance > 100kW/100pF
Overload Indication Red LED indicates input > selected range
Reference Conditions 18° to 28°C, 20 to 75% RH, external magnetic field <40A/m, no DC component, no external current carrying conductor, test sample centered, 1MW £100pF load, zero adjustment prior to measurement [DC only] DC to 65Hz, battery voltage 9V ±0.1V
Working Voltage 600VAC
Influence of Adjacent Conductor
Range Value 50Hz at 23 mm from the probe
Influence of Adjacent Conductor < 10mA/A
Influence of Conductor Position
Influence of Conductor Position 0.5% Reading (DC to 440Hz)
Influence of Humidity
Influence of Humidity 10 to 90%: £0.1%
Rise Fall Time
Range Value 150A, 1500A
Rise Time £100µs froµ 10 to 90% Vout, £70µs froµ 10 to 90% Vout
Noise
Current Range 150A, 1500A
Range Value DC to 1kHz, DC to 5kHz, 0.1Hz to 5kHz, DC to 1kHz, DC to 5kHz, 0.1Hz to 5kHz
Noise £8mV or 0.8A (peak to peak), £12mV or 1.2A (peak to peak), £2mV or 0.2A (peak to peak), £1mV or 1A (peak to peak), £1.5mV or 1.5A (peak to peak), £500µV or 0.5A (peak to peak)
Output Signal
Range Value 150A, 1500A
Output Signal 10mV/A, 1mV/A
Phase
Range 150A, 1500A
Range Value 45 to 65Hz
Current Range Value 10 to 20A, 20 to 100A, 10 to 200A, 200 to 1000A
Phase Shift £3°, <2°, <1.5°
Mechanical Specifications
Altitude Operating: 0 to 2000m; Non-operating: 0 to 12km
Auto Off 10 minutes (may be disabled at power-up by pressing Zero button on; green LED blinks three times to indicate auto-off is disabled
Battery Life Approximately 50 hours with alkaline battery
Colors Dark gray handles with red jaws
Dimensions 9.31 x 3.82 x 1.73" (236.5 x 97 x 44mm)
Drop Test 1.0m on 38mm of oak on concrete; (IEC 68-2-32)
Jaw Opening 1.55" (40mm)
Low Battery Green LED on when battery voltage ³6.5V
Material Jaws: Polycarbonate with 10% fiberglass charge, Red UL 94 V0; Case: Polycarbonate
Maximum Bus Bar Size Two bus bars 1.96 x 0.19" (50 x 5mm) or one bus bar 1.96 x 0.49" (50 x 12.5mm)
Maximum Cable Diameter One 1.5" (39mm) or two 0.98" (25mm)
Mechanical Shock 100g per IEC 68-2-27
Operating Temperature 14° to 131°F (-10° to 55°C)
Operating Relative Humidity 10-35°C 90 ±5% RH (without condensation); 40-55°C 70 ±5% RH (without condensation)
Output Double insulated 5 ft (1.5m) lead with safety banana plugs
Power Supply 9V Alkaline (NEDA 1604A, IEC 6LR61)
Protection Index (IP) IP30 (IEC 529)
Impact Test IK04 0.5 J EN50102
Storage Temperature -40° to 176°F (-40° to 80°C)
Vibration Test per IEC 68-2-6
Vibration
Range Value 5 to 15Hz, 15 to 25Hz, 25 to 55Hz
Vibration Amplitude: 1.5 mm per IEC 68-2-6, Amplitude: 1 mm per IEC 68-2-6 Amplitude : 0.25 mm per IEC 68-2-6
Weight 1.06 lbs (480g)
Zero Adjustment Automatic zero ± 10A by simple push button
External Influences
Influence of Temperature £300 ppm/°K or 0.3% /10K°
Safety Reference Specifications
Safety Ratings EN 61010-2-32
Agency Approvals CE Mark




 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 




AEMC 110% Price Match Guarantee

Quote Request

We Take POs, How To Order

Free Shipping on AEMC










Live chat by BoldChat
Need help? We have a staff
of more than 30 people to help you.
Let us show you why over 100,000
customers choose Tequipment.NET