| Operating Range |
| Current Range |
2 to 150AAC, continuous duty cycle |
| Frequency Range |
45 to 1000Hz |
| Common Mode Voltage |
30VAC |
| Current Overload |
170A continuous |
| Load Impedance |
5W max noninductive |
| Reference Conditions |
23°C ± 3°K, 20 to 85% RH, external magnetic field <40A/m, no DC component, no external current carrying conductor, test sample centered. Load impedance 1w |
| Ratio |
| Ratio |
1000:1 |
| Working Voltage |
600VAC |
| Output Signal |
| Output Signal |
1mAAC/AAC (150mA at 150A) |
| Accuracy |
| Current Range |
1 to 100A AC |
| Range Value |
45 to 65Hz / 45 to 656Hz / 65 to 1000Hz |
| Accuracy % of Reading |
± 2% Reading ± 0.1A / ± 2.5% Reading ± 0.15A / ± 4.5% Reading ± .0.15A |
| Phase |
| Range Value |
50 to 60Hz |
| Current Range Value |
1 to 120A |
| Phase Shift |
£10° |
| Mechanical Specifications |
| Colors |
Dark gray handles with red cover |
| Dimensions |
1.26 x 4.5 x 0.87" (32 x 115 x 22mm) |
| Material |
Handles: 10% Fiberglass charged polycarbonate UL 94 V0 |
| Maximum Cable Diameter |
0.47" & Oslash; max. (12mm) |
| Operating Temperature |
14° to 122°F (-10° to 50°C) |
| Output |
5 ft (1.5m lead with safety 4mm banana plug |
| Storage Temperature |
-40° to 176°F (-40° to 80°C) |
| Vibration |
Test per IEC 68-2-6 |
| Weight |
5.6 oz (160g) |
| External Influences |
| Influence of Temperature |
<0.2% per 10K° |
| Safety Reference Specifications |
| Safety Ratings |
30V max common mode between output and ground; 3kV 50/60Hz dielectric |