Features:
  • 2 independent input channels
  • User-selectable ranges of 0 to 100mV; 0 to 1V and 0 to 10VDC per channel
  • Programmable storage rates from 8 every second to 1 every day
  • 3 user selectable storage modes; Stop when full, FIFO; XRM
  • Stores up to 240,000 measurements in non-volatile memory
  • Powered by two standard AA Alkaline batteries
  • Lightweight, compact, fits anywhere
  • 5 LED indicators quickly and clearly display Logger status
  • Includes DataView software FREE for data storage, real-time display, analysis and report generation
  • 50V Cat III


Applications:
  • Circuit design troubleshooting
  • Sensor monitoring
  • Battery testing
  • Power supply profiling

Includes:
  • Typa A to 5-pin mini-B USB 2M
  • DataView Software CD
  • Two 1.5V AA-cell Alkaline batteries
  • User manual



  Description

L432 AC Current Loggers

The Simple Logger II Model L432 is a two channel DC data logger. The choice of data storage modes and storage rates allows the operator to effortlessly configure the logger to optimize memory usage to the application at hand. Extended Recording Mode (XRM) and delayed start time are just two of the many application friendly features.

The Simple Logger II Model L432 records DC voltage at user selectable rates from 8 per second to 1 per day. Voltages can be measured up to 10V with 0.01V resolution in user selectable ranges of 0-100mV, 0-1V and 0-10VDC.

The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using DataView software.

Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and time information. An optically isolated Universal Serial Bus (USB) port provides for the transfer of data from the instrument’s internal memory to the computer for analysis.




DataView Graphing & Analysis Software

The DataView software provides a convenient way to configure and control logging from your computer. Through the use of clear and easy-to-use tabbed dialog boxes, all Simple Logger II functions can be configured and tests can be initiated. Results can be displayed in real time and stored in your PC or the logger. Standard or custom reports may be printed along with the operator’s comments and analysis.

Software Features

  • Display and analyze real-time data on your PC
  • Configure all Data Logger functions and parameters from your PC including sample rate, recording length, channel configuration and more
  • Select storage mode for optimum recording
  • Zoom in and out and pan through sections of the graph to analyze the data
  • Download, display and analyze recorded data
  • Display waveforms, trend graphs, harmonics (AC models) and text summaries, all in real-time
  • Create custom views and reports
  • Print reports using standard or custom templates you design
  • Free software upgrades
AEMC 2126.07
Quick and simple configuration of all functions and settings from one dialog box.
AEMC 2126.07
Real-time view of trend, waveform and status screens.
AEMC 2126.07
Configure all alarm functions with straightforward selections.

3 Recording Modes

Start/Stop Mode
In this mode the operator selects a storage rate from predefined values from 8 per second to 1 every day, then selects a start and stop time. Data is recorded at this rate until the memory is filled or the end recording time and date is reached. The logger then stops recording and goes into standby mode retaining the recorded date.

First In First Out Mode (FIFO)
The operator makes the data storage and recording length selections as described above. If the memory fills before the end date and time occurs, the logger will discard the oldest stored data point and add a new one. This process will continue until the end recording date and time is reached.

Extended Time Recording Mode (XRM)
This unique recording mechanism provides for continuous recording over a longer period of time without the need for the operator's selection or adjustments. The operator selects a starting storage range from predefined values from 8 per second to 1 every day and a recording length. The logger will store data at the rate selected until the memory is filled. The logger will then discard every other stored sample beyond the first one, freeing up half the memory for continuous recording. New samples will be stored at half the previous storage rate, matching the interval with the remaining stored data. This process will repeat each time the memory fills until the operator stops the recording manually, the end recording date and time is reached or the battery runs down.




  Models, Options, & Accessories


Model Description List Price Sale Price
2126.07 Simple Logger II Model L432 (2-Channel, DC100mV/1V/10VDC, DataView Software)
$339.00
You may qualify for better pricing.
Please call 877-742-TEST (8378)
or Email for details.
2126.02 Simple Logger II Model L101 (1-Channel, TRMS, 0 to 1VAC, DataView Software)
$339.00
You may qualify for better pricing.
Please call 877-742-TEST (8378)
or Email for details.
2126.03 Simple Logger II Model L102 (2-Channel, TRMS, 0 to 1VAC, DataView Software)
$379.00
You may qualify for better pricing.
Please call 877-742-TEST (8378)
or Email for details.
2126.04 Simple Logger II Model L111 (1-Channel, TRMS, 0 to 1AAC, DataView Software)
$339.00
You may qualify for better pricing.
Please call 877-742-TEST (8378)
or Email for details.
2126.05 Simple Logger II Model L261 (1-Channel, TRMS, 600VAC, DataView Software)
$359.00
You may qualify for better pricing.
Please call 877-742-TEST (8378)
or Email for details.
2126.06 Simple Logger II Model L322 (2-Channel, 4 to 20mADC, Current, DataView Software)
$339.00
You may qualify for better pricing.
Please call 877-742-TEST (8378)
or Email for details.
2126.08 Simple Logger II Model L642 (Temperature Thermocouple, DataView Software)
$359.00
You may qualify for better pricing.
Please call 877-742-TEST (8378)
or Email for details.
2126.35 Simple Logger II Model L562 (2-Channel, TRMS Voltage & Current, DataView Software)
$379.00
You may qualify for better pricing.
Please call 877-742-TEST (8378)
or Email for details.
2126.01 Simple Logger II Model CL601 (1-Channel, TRMS, Clamp-on, 0 to 600AAC, DataView Software)
$469.00
You may qualify for better pricing.
Please call 877-742-TEST (8378)
or Email for details.



  Specifications

Simple Logger II Model L432
Electrical
Channels Two
Input Connection One 4 position removable screw-type terminal block
Measurement Range
(3 ranges/channel)
Range 1: -100mV to 100mVdc
Range 2: -1V to 1Vdc
Range 3: -10V to 10Vdc
Resolution Range 1: 0.1mV
Range 2: 1mV
Range 3: 10mV
Accuracy
(50/60Hz)
Range 1: ±(0.5% of Reading + 1mV)
Range 2: ±(0.5% of Reading + 1mV)
Range 3: ±(0.5% of Reading + 10mV)
Sample Rate Maximum of 8 samples taken at storage interval
Storage Rate Programmable from 125mS to 1 day
Storage Modes Start/Stop, FIFO and Extended Recording Mode (XRM)
Recording Length 15 minutes to 8 weeks, programmable using DataView
Memory 240,000 measurements (512KB) The recorded data is stored in non-volatile memory & retained even if the battery is low or removed.
Communication USB 2.0 optically isolated
Power Source 2 x 1.5V AA-cell Alkaline batteries
Battery Life 100 hours to >45 days (dependent on storage rate/recording length)
Mechanical
Dimensions 5.45 x 2.75 x 1.28" (136 x 70 x 32mm)
Weight (with battery) 6.4 oz (181 grams)
Case UL94-V0
Vibration IEC 68-2-6 (1.5mm, 10 to 55Hz)
Shock IEC 68-2-27 (30G)
Drop IEC 68-2-32 (1m)
Environmental
Operating Temperature 14° to 122°F (-10° to 50°C)
Storage Temperature -4° to 140°F (-20° to 60°C)




 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 




Fluke Sponsored March Madness Bracket Challenge

AEMC 110% Price Match Guarantee

Quote Request

We Take POs, How To Order

Free Shipping on AEMC










Live chat by BoldChat
Let our engineers and cs staff help!
Need a quote? Need to check stock?
Have a technical question? No problem.
We are here to help.