AEMC L215 2116.07 AC Exception Voltage Logger

Click image to enlarge
AEMC 2116.07
|
|
Features:
- 0 to 250Vrms
- 10 samples per second
- Stores data when alarm level is tripped
- True RMS measurements
- 64K storage memory
- 10 bit resolution (250mV)
- Detect sags and swells
- Scale automatically selected by software
- Software programmable HI and LO alarm levels
- Alarm trip LED indicator
- Includes Software(CD-ROM), 6ft. DB-9 RS-232 Cable, 9V battery, 5ft lead set, and User Manual
|
Description
|
The AC Exception Voltage Simple Logger Model L215 is the ideal product to capture short-term events such as sags and swells. This logger samples the input 10 times per second and only stores the data when an alarm threshold is crossed, thus maximizing its use of memory. The 65,000-point storage capacity provides enough memory to store more than 1000 events. The Model L215 is powered by the AC voltage signal it is monitoring and incorporates a backup battery to provide up to one year of additional operation and data storage protection.
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| 2116.07 |
Simple Logger Model L215 (RMS Voltage, 0 to 250VAC Input) |
$349.00
 |
| You may qualify for better pricing. |
| Please call 877-742-TEST (8378) |
| or Email for details. |
|
|
| Model |
Accessories |
List Price |
Sale Price |
| 2118.49 |
Adapter 110V Outlet Adapter w/Banana Jacks for Models L230 & L260 |
$24.25
 |
| You may qualify for better pricing. |
| Please call 877-742-TEST (8378) |
| or Email for details. |
|
|
| 2118.51 |
Lead Set of 2, Color-coded 5 ft Voltage Leads, 4mm Straight End, 2 Color-coded Alligator Clips for Models L205, L230, L260, L410 & L430 See Replacement Cat. #2140.62 - Discontinued - no replacement |
| 2114.26 |
Simple Logger+ Software Upgrade for all Models |
$49.00
 |
| You may qualify for better pricing. |
| Please call 877-742-TEST (8378) |
| or Email for details. |
|
|
Specifications
| Electrical Specifications |
| Number Of Channels |
1 |
| Measurement Range |
0 to 250Vrms |
| Input Connections |
Recessed safety banana jacks |
| Resolution |
10 bit, 250mV max |
| Accuracy |
1% of Reading +250mV |
| Sample Rate |
36,000/hr (10 samples/sec) |
| Data Storage |
Approximately 65, 536 readings |
| Data Storage Technique |
Exception recording in FIFO mode; 60 samples stored when alarm is tripped. Each 60 sample recording is considered to be a packet. When memory is full, data will be overwritten one packet at a time beginning with the oldest. |
| Power Source |
AC powered with 9V Alkaline battery backup |
| Battery Life |
Up to 1 yr of recording @ 25° C |
| Output |
RS-232 via DB9 connector (@4800 baud) |
| Indicators |
Red LED double flashes in LOGGING, single flashes in STANDBY and is off in OFF mode. Amber LED flashes once every 2 seconds when alarm level has been tripped. Amber light can only be reset by stopping the recording and downloading the data. |
| Controls |
One button used to start and stop recording sessions and to turn the data logger on and off |
| Mechanical Specifications |
| Size |
2-7/8 x 2-5/16 x 1-5/8" (73 x 59 x 41mm) |
| Weight |
5 oz (140g) |
| Mounting |
Base plate mounting holes or Velcro pads supplied loose |
| Case Material |
Polystyrene UL VO |
| Environmental Specification |
| Operating Temperature |
-4° to +158°F (-20° to +70°C) |
| Storage Temperature |
-40° to +174°F (-40° to + 80°C) |
| Relative Humidity |
5 to 95% non-condensing |
| Protection Index |
NEMA2 |
| Software Compatibilty |
Windows 3.1, Windows 95, Windows 98 |
| Safety Reference Specifications |
| Safety Rating |
EN 61010, 30V, Cat. III |
|