AEMC CL600 2116.11 Clamp-On AC Logger

Click image to enlarge
AEMC 2116.11
|
|
Features:
- 0 to 600A input
- Self-contained, no exposed connections
- True RMS measurements
- Overload indication
- One button operation
- RS-232 output
- Includes Software(CD-ROM), 6ft. DB-9 RS-232 Cable, 9V battery, and User Manual
|
Description
|
The Clamp-On Simple Logger Model CL600 is a self-contained data logging AC current probe. The logger requires no user setup and has the ability to automatically adjust its scale and sample rate to optimize themselves to the recording. One button operation makes the clamp-on logger extremely easy and quick to use. True RMS measurements with 0 to 600Arms input. Storage of over 8000 data points with a built in RS-232 port for down loading data. One year operation off a single 9V Alkaline battery. A Windows-based software package is included which allows plotting, statistical analysis, text annotation and zoom capability.
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| 2116.11 |
Simple Logger Model CL600 (Clamp-On, RMS Current, 0 to 600Arms Input) - Discontinued - replaced by AEMC 2126.01 |
| Model |
Accessories |
List Price |
Sale Price |
| 2114.26 |
Simple Logger+ Software Upgrade for all Models - Discontinued - no replacement |
Specifications
| Electrical Specifications |
| Number Of Channels |
1 |
| Measurement Range |
0 to 600Arms |
| Input |
0 to 600Arms |
| Input Connections |
Split Jaw |
| Resolution |
8 bit, 0.5Arms |
| Resolution |
| Scale Range |
100% / 50% / 25% / 12.5% |
| Max Input |
600Arms / 500Arms / 250Arms / 125Arms |
| Resolution |
4Arms / 2Arms / 1Arms / 0.5Arms |
| Accuracy |
2% of Reading + Resolution (0 to 400A), 5% of Reading + Resolution (400 to 600A) |
| Sample Rate |
4096/hr maximum |
| Data Storage |
8192 readings |
| Data Storage Technique |
Time Extension Recording (TXR) |
| Power Source |
9V Alkaline battery |
| Battery Life |
Up to 1 yr of recording @ 25° C |
| Output |
RS-232 via DB9 connector |
| Indicators |
Red LED double flashes in LOGGING, single flashes in STANDBY, and is off in OFF mode |
| Controls |
One button used to start and stop recording sessions an to turn the data logger on and off |
| Working Voltage |
600V |
| Mechanical Specifications |
| Size |
5.47 x 2.00 x 1.8" (139 x 51 x 30mm) |
| Weight |
17.1 oz |
| Jaw Opening |
1.65" (42mm) maximum |
| Max Conductor Size |
2 conductors (25.4mm) each, 1 conductor: 1.65" (42mm) |
| Case Material |
Polycarbonate UL 40 |
| Environmental Specification |
| Operating Temperature |
-4° to +158°F (-20° to +70°C) |
| Storage Temperature |
-40° to +174°F (-40° to + 80°C) |
| Relative Humidity |
5 to 95% non-condensing |
| Protection Index |
NEMA2 |
| Software Compatibilty |
Windows 3.1, Windows 95, Windows 98 |
| Safety Reference Specifications |
| Safety Rating |