AEMC CA5230 2116.76 4000-Count Digital Multimeter
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   

   
   




AEMC CA5230 2116.76 4000-Count Digital Multimeter



AEMC 2116.76
Click image to enlarge

 AEMC 2116.76

Features:
  • Tough, reliable, economical 4000-count model
  • Large backlit display
  • Clear pushbutton functions
  • Large rotary range selector and dedicated push buttons
  • Safety rated to EN 61010, 600V Cat. III for protection against spikes and overvoltage
  • Complete line of accessories including leads and industry's largest selection of current probes
  • Includes rugged, shockproof, protective dirt resistant gray holster with Multistand (for lead and probe storage) and test leads
  • Three year warranty



  Description

The tough, reliable, economical CA5230 Digital Multimeter (DMM ) with a 4000-count display is TRMS and provides 0.25% accuracy of reading. The multimeter has a large backlit display, clear push-button functions, large rotary range selector and dedicated push buttons. The compact, hand-held size along with the rugged, shockproof rubber holster makes this unit ideal for toolboxes and pockets. The Model CA5230 is rated to EN 61010, 600V Cat. III for protection against spikes and over-voltage.



  Models, Options, & Accessories


Model Description List Price Sale Price
2116.76 DMM Model CA5230 (4000-count, TRMS, 0.25% Accuracy), Model CA5230 - Discontinued - suggested replacement: Extech EX470 or Extech EX520
2116.73 DMM Model CA5205 (2000-count, Average Sensing, 1% Accuracy), Model CA5205 - Discontinued - suggested replacement: Extech EX470 or Extech EX520
2116.74 DMM Model CA5210 (4000-count, Average Sensing, 1% Accuracy), Model CA5210 - Discontinued - suggested replacement: Extech EX470 or Extech EX520
2116.75 DMM Model CA5220 (4000-count, Average Sensing, 1% Accuracy), Model CA5220 - Discontinued - suggested replacement: Extech EX470 or Extech EX520
2116.77 DMM Model CA5240 (40,000-count, TRMS, 0.1% Accuracy), Model CA5240 - Discontinued - suggested replacement: Extech EX470 or Extech EX520



  Specifications

AC Voltage
AC/DC VOLTAGE 5 ranges: 400mV to 600V
RANGE 400mV (Accessible by the RANGE button. Minimum measurement: 20mV) / 4V 40V / 400V / 600V (Crest factor FC £3)
ACCURACY ±1.5% Reading ±5cts / ±1% Reading ±3cts
V DC IMPEDANCE 100MW / 10MW / 9.1MW
RESOLUTION 0.1mV / 1mV / 10mV / 100mV / 1V
BARGRAPH RESOLUTION 100mV / 1V / 10V / 100V
PERMITTED OVERLOAD 600VRMS and 1000V peak
AC Current
RANGE 40mA / 400mA / 10A (Crest fcator FC £3)
FREQUENCY RANGE 40Hz to 1000Hz
ACCURACY ±1.2% Reading ±4cts / ±1.5% Reading ±5cts
PROTECTION Fuse 0.5A HBC
PERMITTED OVERLOADS 12A for 30 seconds
RESOLUTION 10µA / 100µA / 10mA
VOLTAGE DROP (at the terminals) 450mV / 650mV / 400mV
BARGRAPH RESOLUTION 1mA / 10mA / 1A
DC Voltage
RANGE 400mV (Accessible by the RANGE button. Minimum measurement: 20mV) / 4V 40V / 400V / 600V (Crest factor FC £3)
ACCURACY ±0.25% Reading ±1ct
V DC IMPEDANCE 100MW / 10MW / 9.1MW
RESOLUTION 0.1mV / 1mV / 10mV / 100mV / 1V
BARGRAPH RESOLUTION 100mV / 1V / 10V / 100V
PERMITTED OVERLOAD 600VRMS and 1000V peak
DC Current
RANGE 40mA / 400mA / 10A (Crest fcator FC £3)
ACCURACY ±0.8% Reading ±2cts / ±1.2% Reading ±4cts
PROTECTION Fuse 0.5A HBC
RESOLUTION 10µA / 100µA / 10mA
VOLTAGE DROP (at the terminals) 450mV / 650mV / 400mV
BARGRAPH RESOLUTION 1mA / 10mA / 1A
BASIC ACCURACY 0.25%
VOLTAGE FREQUENCY 0 to 60Hz
IMPEDENCE 10MW
AC/DC CURRENT 3 ranges: 40mA to 10A
CURRENT FREQUENCY 0 to 60Hz
Resistance
RESISTANCE 6 ranges: 400W to 40MW
RANGE 400W / 4kW / 40kW / 400kW / 4MW / 40MW
ACCURACY ±1% Reading ±4cts / ±0.5% Reading ±3cts / ±1% Reading ±4cts / ±1.5% Reading ±4cts
PROTECTION 500VRMS and 750V peak
RESOLUTION 0.1W / 1W / 10W / 100W / 1kW / 10kW
BARGRAPH RESOLUTION 10W / 100W / 1kW / 10kW / 100kW / 1MW
VOLTAGE ON THE OPEN CIRCUIT £0.4V DC
Continuity Beeper
CONTINUITY BEEPER R < 40W
CONTINUITY BEEPER On the 400W range, continuos beep for a resistance R£40W
RESPONSE TIME 100ms
Diode Test
DIODE TEST measurement of the voltage in forward direction (resolution 1mV)
RESOLUTION 1mV
ACCURACY ±1% Reading ±2cts
OPEN CIRCUIT VOLTAGE 3.2V typical
SHORT CIRCUIT CURRENT 0.6mA
COMMENT in reverse direction the display indicates the open circuit voltage, around 4V
Capacitance
CAPACITANCE 5 ranges: 4nF to 40mF
CAPACITANCE METER FUNCTION 4nF / 40nF / 400nF / 4mF / 40mF (For a capacitance C>20mF, the accuracy is ±5% Reading ± 8 counts)
ACCURACY ±1.5% Reading ±40cts / ±1.5% Reading ±4cts
PROTECTION 500VRMS and 750V peak
RESOLUTION 1pF / 10pF / 100pF / 1nF / 10nF
Frequency
FREQUENCY 5 ranges: 100Hz to 400kHz
ACCURACY ±0.1% Reading ±10cts / ±0.1% Reading ±4cts / ±0.1% Reading ±8cts / ±0.1% Reading ±20cts
RANGE 100Hz / 1kHz / 10kHz / 100kHz (Note: If the frequency applied is 99.99kHz, the decimal point oscillates between .999kHz and 99.99kHz) 400kHz
RESOLUTION 0.01Hz / 0.1Hz / 1Hz / 10Hz / 100Hz
PERMITTED OVERLOAD 500VRMS and 900V peak
OPERATING RANGE The RANGE button selects the trigger level: 10m / 4V to 600V
MIN/MAX over 500ms
RANGE SELECTION automatic and manual range
Measurement Rate
AC/DC VOLTAGE 1
AC/DC CURRENT 1
RESISTANCE 1
CONTINUITY AUDIBLE TEST 1
DIODE TEST 1
CAPACITANCE 1
FREQUENCY 1
MIN/MAX VALUE 1
HOLD DISPLAY 1
BACKLIGHT 1
General Specifications
POWER OFF automatic (30 min) or manual
POWER SUPPLY 1 battery 9V (6LF22)
BATTERY LIFE 500 hours
BUZZER Continuous beep for the continuity test, Intermittent beep each time the switch or buttons are pressed, and for the overload indication
MECHANICAL DIMENSIONS 7.0 x 2.5 x 1.7" (177 x 64 x 42 mm)
WEIGHT 0.7 lbs (350 g)
Environmental Specification
ENVIRONMENT Use / Storage
TEMPERATURE 0°C to +50°C / -20°C to +60°C
RELATIVE HUMIDITY £70%RH / £90%RH (up to 45°C)
ALTITUDE <2000m
Safety Reference Specifications
CE Mark CE MARK
Electrical Safety (per brochure) IEC 1010, 1600V CAT III
Protection (per brochure) Electronic and HBC fuses 0.5A & 12A
Protection Index (per brochure) IP40
Electrical Safety (per manual) Double Insulation
Degree of pollution 2
Installation category III
Assigned voltage 600VRMS
Electromagnetic Compatiility Emission (EN 50081-1) / Immunity (EN 50082-1)
Mechanical Protection (per manual) Degree of watertightness (IEC 529): protection index IP 40
Note This multimeter of overvoltage category III satisfies the severe requirements of reliability and availability corresponding to industrial and domestic permanent installations (IEC 664-1)



   