AEMC 512 2117.68 Clamp-on Meter TRMS

Click image to enlarge
AEMC 2117.68
|
|
Features:
- TRMS
- Standard size, full function clamp-on meter
- 1000AAC current measurements
- 750VAC/1000VDC volt measurements
- Resistance measurement to 4000Ω
- Continuity with beeper below 40Ω
- Frequency measurements from V and A
- Diode test
- 1ms Peak function for fast capture of signals
- Hold function to "freeze" readings
- Push-button for easy ADC zeroing
- Large easy-to-read 4000-count display
- 42-segment analog bargraph
- Includes test leads and soft carrying pouch
|
Description
The Clamp-On Meter Model 512 is a general purpose professional clamp-on meter that measures up to the toughest standards. It is built into a rugged mechanical case and is designed using quality polycarbonate materials. This meter offers a complete set of measurement ranges and is in compliance with international safety and quality standards to ensure a professional and reliable measuring tool. The Model 512 is auto-ranging and provides the best measurement range and resolution for troubleshooting. It has a high resolution 40A range.
The Model 512 measures AC Amps, AC Volts, DC Volts, Ohms, Continuity (with beeper), Frequency (from V or A) and has a Diode Test function. The Model 512 is sized for a comfortable, one-handed operation. This model is a True RMS clamp-on that provides RMS measurements for today's non-linear electrical environments. The jaw opening for the Model 512 is 1.575" (40mm).
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| 2117.68 |
Clamp-On Meter Model 512 (TRMS, 1000AAC, 600VAC/DC, Ohms, Continuity) |
$159.00
 |
| You may qualify for better pricing. |
| Please call 877-742-TEST (8378) |
| or Email for details. |
|
|
| 2117.67 |
Clamp-On Meter Model 511 (AC, 1000AAC, 600VAC/DC, Ohms, Continuity) |
$149.00
 |
| You may qualify for better pricing. |
| Please call 877-742-TEST (8378) |
| or Email for details. |
|
|
| 2117.70 |
Clamp-On Meter Model 514 (AC/DC, TRMS, 1000AAC/DC, 600VAC/DC, Ohms, Continuity) |
$199.00
 |
| You may qualify for better pricing. |
| Please call 877-742-TEST (8378) |
| or Email for details. |
|
|
Specifications
| AC Current |
| Range |
0.05A to 1000A |
| Resolution |
40A: 0.01A; 400A: 0.1A; 1000A: 1A |
| Basic Accuracy |
50 to 500Hz: ±1.9% of Reading + 5cts |
| Frequency Range |
50 to 500Hz |
| Overload Protection |
40A: 800Arms; 400A: 1500Arms; 1000A: 1500Arms |
| AC Volts |
| Input Range |
0.5V to 750V |
| Range |
400V / 750V |
| Resolution |
0.1V / 1V |
| Accuracy |
±1.2% of Reading + 5cts |
| Input Impedance |
10MW |
| Overload Protection |
1000Vrms |
| Frequency Current Input |
| Range |
4kHz |
| Resolution |
1Hz |
| Minimum Input Signal |
2Arms |
| Accuracy |
±0.1% of Reading + 1ct |
| Frequency Voltage Input |
| Range |
10kHz |
| Resolution |
10Hz |
| Minimum Input Signal |
5Vrms |
| Accuracy |
±0.1% of Reading + 1ct |
| DC Volts |
| Range |
0.2 to 1000V |
| Resolution |
400V: 0.1V; 1000V: 1V |
| Accuracy |
±0.75% of Reading + 2cts |
| Input Impedance |
10MW |
| Overload Protection |
1200Vrms |
| Continuity |
| Range |
Beeper |
| Measurement |
<40W |
| Max. Test Voltage |
3VDC |
| Overload Protection |
600Vrms |
| General Specifications |
| Digital Display |
Digital: 3¾ digits LCD display, 4000 count (max. reading 3999) |
| Analog Display |
Fast 42-segment analog bargraph display |
| Symbol & Scale Range |
Automatic according to range and input signal |
| Polarity |
Minus sign displayed when negative signal applied to input |
| Overload |
OL Displayed when input signal exceeds range |
| Sample Rate |
2 samples/sec for the digital display; 20 samples/sec for the analog bargraph |
| Jaw Opening Size |
1.575" (40mm) |
| Battery |
9V, NEDA 1604 or 6F22 or 006P |
| Low Battery Indicator |
Symbol displayed when the battery is below the required voltage |
| Auto Power Off |
The meter will power itself OFF if there is no push button or rotary switch operation for 30 minutes |
| Dimensions |
9.53 x 2.60 x 1.42" (242 x 66 x 36mm) |
| Weight |
14.10oz (400g) with batteries |
| Environmental Specification |
| Operating Temperature |
32° to 104°F (0° to 40°C), <80% RH, non-condensing |
| Storage Temperature |
14° to 140°F (-10° to 60°C), <70% RH, battery removed |
| Operating Altitude |
2167 ft (2000m) |
| Safety / Reference Specifications |
Safety / Reference Specifications |
| Protection Level |
Double insulation; EN 61010, 600V, Cat. III and EN 61010, 1000V, Cat. II |
| Agency Approvals |
CE Mark |
|