AEMC 501 2117.21 Clamp-on Meter Average Sensing

Click image to enlarge
AEMC 2117.21
|
|
Features:
- Average Sensing
- Compact size - fits into your pocket
- 400AAC or 400AAC/DC current measurements
- 600VAC/DC volts measurements
- Resistance measurements to 400Ω
- Continuity with beeper below 40Ω
- Frequency measurements from V and A
- Hold function to "freeze" readings
- Large easy-to-read 4000-count display
- 42-segment bargraph
- Includes test leads and a soft carrying pouch
|
Description
The Clamp-On Meter Model 501 is a general-purpose professional clamp-on. This compact meter is built with a strong case design, quality materials, full ranges and compliance to international safety and quality standards ensure a professional and reliable measuring tool. The Model 501 is auto-ranging, and provides the user with AC Volts, DC Volts, AC Amperes, resistance, and continuity. The Model 501 also includes a frequency function.
The large and complete 4000-count LCD features comprehensive user interface symbols such as a low battery indicator. It is equipped with a Data Hold function, which freezes the measurement. The Model 501 is compact for comfortable one-handed operation, and the hooked jaw design is easy to maneuver in crowded wiring and breaker panels. The jaw opening for the Model 501 is 1.1" (28mm).
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| 2117.21 |
Clamp-On Meter Model 501 (400AAC, 600VAC/DC, Ohms, Continuity) |
$99.00
 |
| You may qualify for better pricing. |
| Please call 877-742-TEST (8378) |
| or Email for details. |
|
|
| 2117.22 |
Clamp-On Meter Model 503 (AC/DC, 400AAC/DC, 600VAC/DC, Ohms, Continuity) |
$149.00
 |
| You may qualify for better pricing. |
| Please call 877-742-TEST (8378) |
| or Email for details. |
|
|
| 2117.66 |
Clamp-On Meter Model 502 (TRMS, 400AAC/DC, 600VAC/DC, Ohms, Continuity) |
$119.00
 |
| You may qualify for better pricing. |
| Please call 877-742-TEST (8378) |
| or Email for details. |
|
|
| 2117.54 |
Clamp-On Meter Model 500 (400AAC, 600VAC, Ohms, Continuity) |
$69.00
 |
| You may qualify for better pricing. |
| Please call 877-742-TEST (8378) |
| or Email for details. |
|
|
Specifications
| AC Current |
| Range |
0.05 to 400A |
| Resolution |
40A: 0.01A; 400A: 0.1A |
| Basic Accuracy |
50 to 60Hz: ±1.9% of Reading + 5cts; 60 to 500Hz: ±2.5% of Reading + 5cts |
| Frequency Range |
50 to 500Hz |
| Overload Protection |
600Arms |
| AC Volts |
| Input Range |
0.5 to 600V |
| Range |
400V / 600V |
| Resolution |
0.1V / 1V |
| Accuracy |
50 to 60Hz: ±0.8% of Reading + 5cts; 60 to 500Hz: ±1.5% of Reading + 5cts |
| Input Impedance |
1MW |
| Overload Protection |
600Vrms |
| Frequency Current Input |
Frequency Current Input |
| Range |
4kHz, 10kHz |
| Resolution |
1Hz, 10Hz |
| Minimum Input Signal |
2Arms |
| Accuracy |
±0.1% of Reading + 1ct |
| Input Impedance |
1MW |
| Overload Protection |
600Arms |
| Frequency Voltage Input |
| Range |
4kHz, 40kHz, 400kHz |
| Resolution |
1Hz, 10Hz, 100Hz |
| Minimum Input Signal |
5Vrms |
| Accuracy |
±0.1% of Reading + 1ct |
| Input Impedance |
1MW |
| Overload Protection |
600Vrms |
| DC Volts |
| Range |
0.2 to 600V |
| Resolution |
400V: 0.1V; 600V: 1V |
| Accuracy |
±1% of Reading + 2cts |
| Input Impedance |
1MW |
| Overload Protection |
600Vrms |
| Continuity |
| Range |
Beeper |
| Measurement |
<40W |
| Max. Test Voltage |
1.5VDC |
| Overload Protection |
600Vrms |
| General Specifications |
| Digital Display |
3¾ digits LCD display, 4000 count (max. reading 3999) |
| Analog Display |
Fast 42-segment analog bargraph display |
| Symbol & Scale Range |
Automatic according to range and input signal |
| Polarity |
Minus sign displayed when negative signal applied to input |
| Overload |
OL Displayed when input signal exceeds range |
| Sample Rate |
2 samples/sec for the digital display; 20 samples/sec for the analog bargraph |
| Jaw Opening Size |
1.02" (26mm) |
| Battery |
Two 1.5V AAA batteries |
| Low Battery Indicator |
Symbol displayed when the battery is below the required voltage |
| Auto Power Off |
The meter will power itself OFF if there is no push button or rotary switch operation for 30 minutes |
| Dimensions |
7.60 x 1.97 x 1.1" (193 x 50 x 28mm) |
| Weight |
8.11oz (230g) with batteries |
| Environmental Specification |
| Operating Temperature |
32° to 104°F (0° to 40°C), <80% RH, non-condensing |
| Storage Temperature |
14° to 140°F (-10° to 60°C), <70% RH, battery removed |
| Operating Altitude |
2167 ft (2000m) |
| Safety / Reference Specifications |
Safety / Reference Specifications |
| Protection Level |
Double insulation; EN 61010-1, 600V, Cat. III, Pollution degree 2 |
| Agency Approvals |
CE Mark |
|